In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. A170-E1-01
OMRON Corporation
Electronic Components Company
Switch Division
Manual Switch Department
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7096/Fax: (81)75-344-7188
Safety Precautions
● Cautions
Use the Pushbutton Switch within the rated voltage and current
ranges, otherwise the Pushbutton Switch may have a shortened life
expectancy, radiate heat, or burn out. This particularly applies to the
instantaneous voltages and currents when switching.
● Handling
Do not apply excessive operating force to the Switch. Otherwise the
Switch may be damaged or deformed, and the switch mechanism
may malfunction as a result. Apply an operating force not exceeding
9.8 N. Apply the operating load from the side of the striker. Do not
apply a load from an angle or from above the striker. Doing so may
deform the Switch contact.
● Soldering
Observe the following conditions when soldering the Pushbutton
Switch.
Automatic Soldering Bath
Soldering temperature: 260
°C max. (Preheating: 100°C 120 s)
Soldering time: 5 s max.
Manual Soldering
Soldering temperature: 350
°C at the tip of the soldering iron.
Soldering time: 3 s max.
● Washing
Apply alcohol or fluorine based solvents to clean.
Do not clean the switch immediately after soldering. Wait for at least
five minutes after soldering before cleaning.
Ultrasonic cleaning is not available dip into the switch washing
agents for two minute maximum.
● Using Flux
Making mistakes in the type of flux or in the amount or method in
which it is applied can cause flux to enter the interior of the Switch,
with adverse effects on Switch performance. Assess the proper flux,
conditions, and methods prior to using it.
● RoHS Compliant
The "RoHS Compliant" designation indicates that the listed models
do not contain the six hazardous substances covered by the RoHS
Directive.
Reference: The following standards are used to determine compli-
ance for the six substances.
Lead: 1,000 ppm max.
Mercury: 1,000 ppm max.
Cadmium: 100 ppm max.
Hexavalent chromium: 1,000 ppm max.
PBB: 1,000 ppm max.
PBDE: 1,000 ppm max.
● Environment for Storage and Use
To prevent discoloration of the terminals and other problems during
storage, do not store the switch in locations subject to the following
conditions.
1. High temperatures or humidity
2. Corrosive gases
3. Direct sunlight
Also, the switch is not waterproof or splash-resistant. Do not install or
use the switch in locations that are subject to contact with water.
Do not subject the switch to freezing or condensation.
● Packing
100 per plastoc bag.
Printed in Japan
0108 (0108)