
3
A6300
Electrical Characteristics
V
INPUT
= 6.0 V, C
L
= 10
μ
F + 100 nF, C
INPUT
= 22
μ
F, T
J
= -40 to +85
°
C, unless otherwise specified
Parameter
Symbol
Test Conditions
Min.
Min.
25
°
C
Typ.
Max.
25
°
C
Max.
Unit
Supply current
Supply current
1)
I
SS
I
SS
Reset output open, I
L
= 100
μ
A
Reset output open, I
L
= 100 mA
at V
INPUT
= 8.0 V
I
= 100
μ
A
100
μ
A
≤
I
L
≤
100 mA,
-40
°
C
≤
T
J
≤
+125
°
C
100
310
μ
A
1.7
4.2
5.12
mA
V
Output voltage
Output voltage
V
OUTPUT
V
OUTPUT
4.88
4.85
5.15
V
Output voltage temperature
coefficient
2)
Line regulation
3)
V
th(coeff)
V
LINE
50
180
ppm/
°
C
6 V
≤
V
INPUT
≤
26 V, I
L
= 1 mA,
T
= +125
°
C
100
μ
A
≤
I
L
≤
100 mA
I
L
= 100
μ
A
I
L
= 100 mA
I
= 100 mA,
-40
°
C
≤
T
J
≤
+125
°
C
V
INPUT
= 4.5 V, I
L
= 100
μ
A
8)
T
J
°
C, I
= 50 mA,
V
INPUT
= 26 V, T = 10 ms
OUTPUT tied to V
SS
0.2
0.2
40
380
0.5
0.6
170
%
%
mV
mV
Load regulation
3)
Dropout voltage
4)
Dropout voltage
4)
Dropout voltage
4)
V
L
V
DROPOUT
V
DROPOUT
V
DROPOUT
650
1.6
mV
mA
Dropout supply current
Thermal regulation
5)
I
SS
V
thr
1.2
0.05
450
0.25
%/W
mA
Current limit
OUTPUT noise, 10Hz to
100 kHz
Threshold voltage
I
Lmax
V
NOISE
V
TH
V
TH
V
TH
V
TH
V
TH
V
HYS
V
OL
V
OL
V
OL
V
OH
V
OH
V
OH
I
LEAK
200
1.95
2.32
2.73
3.42
3.88
25
175
140
20
4.5
2.6
950
0.05
μ
Vrms
V
V
V
V
V
mV
mV
mV
mV
V
V
mV
μ
A
Version: AA, AG, AM
Version: AB, AH, AN
Version: AC, AI, AO
Version: AD, AJ, AP
Version: AE, AK, AQ
1.77
2.09
2.48
3.11
3.55
1.84
2.18
2.59
3.23
3.70
2.04
2.41
2.86
3.59
4.08
2.17
2.55
3.03
3.80
4.32
Threshold hysteresis
RES Output Low Level
V
OUTPUT
= 5 V, I
OL
= 8 mA
V
OUTPUT
= 3 V, I
OL
= 4 mA
V
OUTPUT
= 1 V, I
OL
= 50
μ
A
V
OUTPUT
= 5 V, I
OH
=- 8 mA
V
OUTPUT
= 3 V, I
OH
= -4 mA
V
OUTPUT
= 1 V, I
OH
= -100
μ
A
V
OUTPUT
= 5 V
400
300
90
RES Output High Level
7)
4.3
2.3
850
Leakage current
6)
1
Table 3
1
)
If INPUT is connected to V
SS
, no reverse current will flow from the OUTPUT to the INPUT, however the supply current specified
will be sank by the OUTPUT to supply the A6300.
2)
The OUTPUT voltage temperature coefficient is defined as the worst case voltage change divided by the total temperature range.
3)
Regulation is measured at constant junction temperature using pulse testing with a low duty cycle. Changes in OUTPUT voltage
due to heating effects are covered in the specification for thermal regulation.
4)
The dropout voltage is defined as the INPUT to OUTPUT differential, measured with the input voltage equal to 5.0 V.
5)
Thermal regulation is defined as the change in OUTPUT voltage at a time T after a change in power dissipation is applied,
excluding load or line regulation effects.
6)
Only for open drain versions.
7)
For push-pull output only
8)
Reset output open