2
A6155
Absolute Maximum Ratings
Parameter
Symbol
Conditions
Continuous voltage at INPUT
to V
SS
Transients on INPUT for
t < 100 ms and duty cycle 1%
Reverse supply voltage on INPUT
Max. voltage at any signal pin
Min. voltage at any signal pin
Storage temperature
Electrostatic discharge max. to
MIL-STD-883C method 3015
Max. soldering conditions
V
INPUT
-0.3 to + 30 V
V
TRANS
V
REV
V
MAX
V
MIN
T
STO
up to + 60 V
- 20 V
OUTPUT + 0.3 V
V
SS
– 0.3 V
-65 to + 150
°
C
V
Smax
T
Smax
1000 V
250
°
C x 10 s
Table 1
Stresses above these listed maximum ratings may
cause permanent damage to the device. Exposure be-
yond specified operating conditions may affect device
reliability or cause malfunction.
Handling Procedures
This device has built-in protection against high static
voltages or electric fields; however, anti-static precau-
tions should be taken as for any other CMOS compo-
nent. Unless otherwise specified, proper operation can
only occur when all terminal voltages are kept within the
supply voltage range. At any time, all inputs must be tied
to a defined logic voltage level.
Operating Conditions
Parameter
Symbol
Min.
Typ.
Max.
Units
Operating junction
temperature
1)
INPUT voltage
2)
OUTPUT voltage
2)3)
RES
&
EN guaranteed
4)
V
OUTPUT
OUTPUT current
5)
Comparator input
voltage
RC-oscillator
programming
Thermal resistance from
junction to ambient
6)
-DIP8
-SO8
T
J
V
INPUT
V
OUTPUT
-40
2.3
1.2
1.2
+85
26
°
C
V
V
V
mA
I
OUTPUT
100
V
IN
0
V
OUTPUT
V
R
10
1000
k
R
th(j-a)
R
th(j-a)
105
160
°
C/W
°
C/W
Table 2
1)
The maximum operating temperature is confimed by
sampling at initial device qualification. In production, all
devices are tested at +85
°
C.
2)
Full operation quaranteed. To achieve the load regulation
specified in Table 3 a 22
μ
F capacitor or greater is required
on the INPUT, see Fig. 8. The 22
μ
F must have an effective
resistance
≤
5
and a resonant frequency above 500 kHz.
3)
A 10
μ
F load capacitor and a 100 nF decoupling capacitor
are required on the regulator OUTPUT for stability. The
10
μ
F must have an effective series resistance of
≤
5
and
a resonant frequency above 500 kHz.
4)
RES must be pulled up externally to V
OUTPUT
even if it is
unused. (Note: RES and EN are used as inputs by EM
test).
5)
The OUTPUT current will not apply for all possible
combinations of input voltage and output current.
Combinations that would require the A6155 to work above
the maximum junction temperature (+85
°
C) must be
avoided.
6)
The thermal resistance specified assumes the package is
soldered to a PCB.