ProASIC3 nano DC and Switching Characteristics
2-32
Revision 11
Table 2-42 2.5 V LVCMOS Low Slew
Commercial-Case Conditions: TJ = 70°C, Worst-Case VCC = 1.425 V, Worst-Case VCCI = 2.3 V
Software Default Load at 10 pF for A3PN020, A3PN015, A3PN010
Drive
Strength
Speed
Grade
tDOUT
tDP
tDIN
tPY
tPYS
tEOUT
tZL
tZH
tLZ
tHZ
Units
2 mA
Std.
0.60
6.40
0.04
1.43
1.63
0.43
6.16
6.40
2.27
2.29
ns
–1
0.51
5.45
0.04
1.22
1.39
0.36
5.24
5.45
1.93
1.95
ns
–2
0.45
4.78
0.03
1.07
1.22
0.32
4.60
4.78
1.70
1.71
ns
4 mA
Std.
0.60
6.40
0.04
1.43
1.63
0.43
6.16
6.40
2.27
2.29
ns
–1
0.51
5.45
0.04
1.22
1.39
0.36
5.24
5.45
1.93
1.95
ns
–2
0.45
4.78
0.03
1.07
1.22
0.32
4.60
4.78
1.70
1.71
ns
6 mA
Std.
0.60
5.00
0.04
1.43
1.63
0.43
4.90
5.00
2.60
2.89
ns
–1
0.51
4.26
0.04
1.22
1.39
0.36
4.17
4.26
2.21
2.46
ns
–2
0.45
3.74
0.03
1.07
1.22
0.32
3.66
3.74
1.94
2.16
ns
8 mA
Std.
0.60
5.00
0.04
1.43
1.63
0.43
4.90
5.00
2.60
2.89
ns
–1
0.51
4.26
0.04
1.22
1.39
0.36
4.17
4.26
2.21
2.46
ns
–2
0.45
3.74
0.03
1.07
1.22
0.32
3.66
3.74
1.94
2.16
ns
Note: For specific junction temperature and voltage supply levels, refer to Table 2-6 on page 2-5 for derating values. Table 2-43 2.5 V LVCMOS High Slew
Commercial-Case Conditions: TJ = 70°C, Worst-Case VCC = 1.425 V, Worst-Case VCCI = 2.3 V
Software Default Load at 10 pF for A3PN020, A3PN015, A3PN010
Drive
Strength
Speed
Grade
tDOUT
tDP
tDIN
tPY
tPYS
tEOUT
tZL
tZH
tLZ
tHZ
Units
2 mA
Std.
0.60
3.70
0.04
1.43
1.63
0.43
3.66
3.70
2.27
2.37
ns
–1
0.51
3.15
0.04
1.22
1.39
0.36
3.12
3.15
1.93
2.02
ns
–2
0.45
2.77
0.03
1.07
1.22
0.32
2.74
2.77
1.69
1.77
ns
4 mA
Std.
0.60
3.70
0.04
1.43
1.63
0.43
3.66
3.70
2.27
2.37
ns
–1
0.51
3.15
0.04
1.22
1.39
0.36
3.12
3.15
1.93
2.02
ns
–2
0.45
2.77
0.03
1.07
1.22
0.32
2.74
2.77
1.69
1.77
ns
6 mA
Std.
0.60
2.76
0.04
1.43
1.63
0.43
2.80
2.60
2.98
ns
–1
0.51
2.35
0.04
1.22
1.39
0.36
2.38
2.21
2.54
ns
–2
0.45
2.06
0.03
1.07
1.22
0.32
2.09
1.94
2.23
ns
8 mA
Std.
0.60
2.76
0.04
1.43
1.63
0.43
2.80
2.60
2.98
ns
–1
0.51
2.35
0.04
1.22
1.39
0.36
2.38
2.21
2.54
ns
–2
0.45
2.06
0.03
1.07
1.22
0.32
2.09
1.94
2.23
ns
Notes:
1. Software default selection highlighted in gray.
2. For specific junction temperature and voltage supply levels, refer to Table 2-6 on page 2-5 for derating values.