High Precision Hall Effect AC-Coupled Differential 
Sensor IC with Integrated Filter Capacitor
A1421, A1422, 
and A1423
5
Allegro MicroSystems, LLC
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
THERMAL CHARACTERISTICS may require derating at maximum conditions, see application information
Characteristic
Symbol
Test Conditions*
Value  Units
Package Thermal Resistance
R
窲A
Minimum-K PCB (single-sided with copper limited to solder pads)   177   篊/W
*In still air. Additional thermal information available on Allegro Web site.
20   40   60   80   100   120   140   160   180
8
10
12
14
0
2
4
6
16
18
20
22
24
26
28
30
(R
JA 
= 177 篊/W)
Minimum-K PCB
V
CC(min)
V
CC(max)
 
20  40  60  80  100  120  140  160  180
Temperature (癈)
(
R
J
A
 =
 
1
7
7
 
?/DIV>
C
/
W
)
M
i
n
i
m
u
m
-
K
 
P
C
B
0
50
100
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
The following provide additional information about some of the 
parameters cited. For additional information, visit the Allegro 
Web site at www.allegromicro.com.
Applied Magnetic Field, B
diff
  The differential magnetic flux 
density, which is calculated as the arithmetic difference of the 
flux densities observed by each of the two Hall elements. f
Bdiff 
is 
the input signal frequency.
Output Off Switchpoint (Operate Point), B
OP
  The value of 
increasing differential magnetic flux density at which the device 
output switches from low to high (A1421) or high to low (A1422 
and A1423).
Output On Switchpoint (Release Point), B
RP
  The value of 
decreasing differential magnetic flux density at which the device 
output switches from high to low (A1421) or from low to high 
(A1422 and A1423).
Power-On Time, t
PO
  The time needed by the device, after 
power is applied, to initialize all circuitry necessary for proper 
operation.
Settling Time, t
Settling
  The time required by the device, after 
t
PO
, and after a valid magnetic signal has been applied, to 
provide proper output transitions. Settling time is a function of 
magnetic offset, offset polarity, signal phase, signal frequency, 
and signal amplitude.
Supply Current (on), I
CC(on)
  The current draw of the device 
with the output transitor is turned on.
Supply Current (off), I
CC(off)
  The current draw of the device 
with the output transitor is turned off.
Response Time, t
Response
  The total time required for generating 
zero-crossing output transitions after initialization (the sum of 
Power-on Time and Settling Time).
De nitions of Terms
Power Derating Curve
T
J(max)
 = 165癈; I
CC
 = I
CC(max)
Maximum Power Dissipation
T
J(max)
 = 165癈; I
CC
 = I
CC(max)
;
 
V
CC
 = V