參數(shù)資料
型號(hào): A1190LUA-T
元件分類: 磁阻傳感器
英文描述: MAGNETIC FIELD SENSOR-HALL EFFECT, 1-20mT, RECTANGULAR, THROUGH HOLE MOUNT
封裝: 1.50 X 4 MM, 3 MM HEIGHT, LEAD FREE, SIP-3
文件頁數(shù): 4/18頁
文件大小: 427K
代理商: A1190LUA-T
Programmable, Chopper-Stabilized,
Two Wire Hall-Effect Switches
A1190, A1192,
and A1193
12
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
To correctly address the fuses to be blown, the code represent-
ing the required parameter value must be translated into a binary
number. For example, as shown in figure 7, decimal code 5 is
equivalent to the binary number 101. Therefore bit 2 must be
addressed and blown, the device power supply cycled, and then
bit 0 must be addressed and blown. The order of blowing bits,
however, is not important. Blowing bit 0 first, and then bit 2 is
acceptable.
Note: After blowing, the programming is not reversible, even
after cycling the supply power. Although a register bit field fuse
cannot be reset after it is blown, additional bits within the same
register can be blown at any time until the device is locked. For
example, if bit 1 (binary 10) has been blown, it is still possible to
blow bit 0. The end result would be binary 11 (decimal code 3).
Locking the Device
After the required code for each parameter is programmed, the
device can be locked to prevent further programming of any
parameters. To do so, perform the following steps:
1. Ensure that the CBLOW capacitor is mounted.
2. Select the Programming Lock register (key 7).
3. Select Blow mode (key 9).
4. Address bit 5 (010000) by sending six VPM pulses.
5. Send one Blow pulse, at IPP and SRBLOW, and sustain it for
tBLOW.
6. Delay for a tLOW interval, then power-down.
7. Optionally check all fuses.
Fuse Checking
Incorporated in the A119x family is circuitry to simultaneously
check the integrity of the fuse bits. The fuse checking feature is
enabled by using the Fuse Check register (selection key 7), and
while in Try mode, applying the codes shown in table 2. The
register is only valid in Try mode and is available before or after
the Programming Lock bit is set.
Setting the fuse threshold high checks that all blown fuses are
properly blown. Setting fuse threshold low checks all un-blown
fuses are properly intact. The supply current increases by 250 μA
if a marginal fuse is detected. If all fuses are correctly blown or
fully intact, there will be no change in supply current.
Additional Guidelines
The additional guidelines in this section should be followed to
ensure the proper behavior of these devices:
A 0.1 μF blowing capacitor, CBLOW, must be mounted between
the VCC pin and the GND pin during programming, to ensure
enough current is available to blow fuses.
The power supply used for programming must be capable of
delivering at least VPH and 175 mA.
Be careful to observe the tLOW delay time before powering
down the device after blowing each bit.
Lock the device (only after all other parameters have been pro-
grammed and validated) to prevent any further programming of
the device.
BOP Selection
Selecting BOP should be done in two stages. First, Try mode
should be used to adjust BOP and monitor the output state. Then
the optimum BOP is set permanently using Blow mode.
Use the BOP Trim Up Counting register to increase the BOP selec-
tion by one Magnetic Step Size, StepBOP, increment with each
bit field pulse (see figure 8). Use the BOP Trim Down Counting
register to decrease the BOP selection by one StepBOPwith each
bit field pulse (see figure 9). As an aid to programming, when
using down-counting method, the A119x automatically inverts
the bit field selection (code 0 in down-counting sets the bit field
value 111111, and the actual bit field value decreases until code
63 sets bit field value 000000).
Note that the release point, BRP, is a value below BOP. The
difference is specified by the Hysteresis, BHYS , which is not
programmable.
相關(guān)PDF資料
PDF描述
A1192LUA-T MAGNETIC FIELD SENSOR-HALL EFFECT, 1-20mT, RECTANGULAR, THROUGH HOLE MOUNT
A1210LLHLT-T MAGNETIC FIELD SENSOR-HALL EFFECT, -15-15mT, 400mV, RECTANGULAR, SURFACE MOUNT
A1211ELHLT-T MAGNETIC FIELD SENSOR-HALL EFFECT, -18-18mT, 400mV, RECTANGULAR, SURFACE MOUNT
A1212EUA-T MAGNETIC FIELD SENSOR-HALL EFFECT, -17.5-17.5mT, 400mV, RECTANGULAR, THROUGH HOLE MOUNT
A1213ELHLT-T MAGNETIC FIELD SENSOR-HALL EFFECT, -20-20mT, 400mV, RECTANGULAR, SURFACE MOUNT
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
A1190LUBTN-T 功能描述:2-WIRE FIELD PROGRAMMABLE SWITCH 制造商:allegro microsystems, llc 系列:* 零件狀態(tài):新產(chǎn)品 標(biāo)準(zhǔn)包裝:1
A1191 制造商:Quick 功能描述:SIP 25L 25mm Nozzle for 21-13205 and 21-13210 制造商:QUICK 功能描述:SIP 25L NOZZLE FOR QUICK957/957D
A-1191-1 功能描述:固態(tài)繼電器-工業(yè)安裝 DC SOLENOID RoHS:否 制造商:Crydom 控制電壓范圍:4 VDC to 32 VDC 負(fù)載電壓額定值:7 VDC to 72 VDC 負(fù)載電流額定值:160 A 觸點(diǎn)形式: 輸出設(shè)備:SSR 安裝風(fēng)格:Panel
A1192 制造商:Quick 功能描述:SIP 50LNOZZLE FOR QUICK957/957D