![](http://datasheet.mmic.net.cn/230000/95678-008-00_datasheet_15573065/95678-008-00_15.png)
TYPE
PRODUCT SPECIFICATION
NUMBER
GS-12-083
TITLE
Single and Multi-Port Modular Jack Assemblies
PAGE
REVISION
15 of 18
F
AUTHORIZED BY
DATE
B. Brubaker
27 Mar 01
CLASSIFICATION
UNRESTRICTED
Copyright 2001 FCI USA, INC.
Form E-3334
02/12/01
GS-01-001
8.9
Six position plug stress test
8.9.1
Eight position, non-keyed jacks with stamped leadframe style terminals shall be
capable of withstanding mating with a six position FCC approved plug and not suffer
overstress damage to pins #1 and #8. After plugging ten times with a six position plug,
pins 1 and 8 shall maintain 70 grams minimum normal force when measured with an
FCC minimum sized plug.
9.0
QUALITY ASSURANCE PROVISIONS
9.1
Equipment Calibration. All test equipment and inspection facilities used in the performance of
any test shall be maintained in a calibration system in accordance with MIL-C-45662 and ISO
9000.
9.2
Inspection Conditions. Unless otherwise specified herein, all inspections shall be performed
under the following ambient conditions:
a) Temperature: 25 +/- 5 degrees C
b) Relative Humidity: 30% to 60%
c) Barometric Pressure: Local ambient
9.3
Sample Quantify and Description. Unless specified otherwise, the sample quantity for each Test
Group in Table 1 shall consist of a minimum of thirty (30) contacts. The 30 contacts shall be
selected from a minimum of three (3) connectors. In connector families where conditions such as
size, type, plating, material type, etc. would be expected to affect test results, samples should
be included to evaluate those conditions in the affected Test Groups of Table 1.
9.3.1
Results obtained from testing multiport assemblies are applicable to similar products of
other number of ports. Multiport assemblies of representative size (typically 4, 6, 8, or
12 ports) shall be used for mechanical and environmental tests assigned to Group 1.
Other test groups can utilize single or multiport assemblies as practical.
9.4
Acceptance
9.4.1
Electrical and mechanical requirements placed on test samples as indicated in
paragraphs 6.0 and 7.0 shall be established from test data using appropriate statistical
techniques or shall otherwise be customer specified, and all samples tested in
accordance with this product specification shall meet the stated requirements.
9.4.2
Failures attributed to equipment, test set-up, or operator error shall not disqualify the
product. If product failure occurs, corrective action shall be taken and samples
resubmitted for qualification.