Bolt-In Fuses
High Current, T ime Lag
ABI
Form No. ABI
Page 1 of 1
BIF Document: 2068
Bussmann
12-17-98
SB98107
Rev. A
Part No.
ABI 75
ABI 100
ABI 125
ABI 150
ABI 175
ABI 200
Amp Rating
75
100
125
150
175
200
Bolt-in high current, time lag fuse. Ampere ratings from 75 to
200 Amps. IR 1,000A @ 32VDC. Ideal for use in high current
heavy-duty applications such as battery and alternator cables.
Preliminary blow times:
% Rating
Time (Seconds)
135
1000
200
30
350
5
600
0.06
100A
ABI
.47"
(12.0)
.53"
(13.5)
.07"
(1.8)
2.46"
(62.5)
2.00"
(51.0)
1.85"
(47.0)
.85"
(21.5)
.61"
(15.4)