Ultrasonic Sensors
30 mm Diameter Analog
940 Series
B84
Honeywell
1
MICRO SWITCH Sensing and Control
1
1-800-537-6945 USA
1F
1-815-235-6847 International
1
1-800-737-3360 Canada
FEATURES
1
Measuring range up to 2000 mm (78.74
in.)
1
High repeatability
ORDER GUIDE
Sensor
Package
Style
30 mm dia.
Stainless Steel
Sensing
Range*
mm (in.)
300 - 2000
(11.81 - 78.74)
150 - 1200
(5.90 - 47.24)
Analog
Output
1.5 - 10 V
Termi-
nation
Cable
Catalog
Listing
940-A4Y-AD-1C0-130E
1.25 - 10 V
Cable
Connector
940-A4Y-AD-1C0
940-A4V-AD-1C0
* Standard target is 120 mm square of mild steel perpendicular to ultrasonic beam.
SPECIFICATIONS
Catalog Listings
940-A4Y-AD-1C0
940-A4V-AD-1C0
Max. Range
1200 mm (47.2 in.)
940-A4Y-AD-1C0-130E
Max. Range
2000 mm (78.74 in.)
Max. Rate
1000 mm (39.37 in.)
300 mm (11.8 in.)
8
°
Max. Rate
600 mm (23.6 in.)
Max. Sensing Distance
Min. Sensing Distance
Beam Angle
POWER SUPPLY
Supply Voltage
Supply Current
Circuit Protection
OUTPUT CHARACTERISTICS
Load Current
Switching Frequency
Repeatability
Linearity
Output Adjustment
Output Mode
Circuit Protection
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Sealing
SPECIAL FEATURES
Hold Input
Synchronization Input
LED Indicator
150 mm (5.91 in.)
10
°
19 - 30 VDC
<
20 mA without load
Reverse polarity
10 mA max.
6 Hz
±
2 mm
11 Hz
±
1 mm
<
0.2%
4 Turn Potentiometer
Max. Range or Max. Rate selected by wiring terminal connection
Short Circuit
0 to 50
°
C (32 to 122
°
F)
0 to 70
°
C (32 to 158
°
F)
IP 65
Stops transmission and reception of sensor when input is connected to 0 VDC. Analog output would be zero.
Avoids mutual interference from several ultrasonic sensors (external synchronization unit required; see Accessories)
Illuminates when sensor detects a target