ELECTRICAL SPECIFICATION
DC Resistance:
Primary
70.4
± 15%
Secondary
70.4
± 15%
Series O/C Inductance:
measured @ 250mV
200Hz >5.5H
2000Hz >1.5H
4000Hz >1.0H
Series O/C AC Resistance:
measured @ 250mV
200Hz >3K
2000Hz >21K
4000Hz >32K
Leakage Inductance:
18mH max.
200Hz - 4000Hz
Harmonic Distortion:
2f: -77dB max.
200Hz, -3dBm on primary,
3f: -75dB max.
600
load on secondary.
TDdBm: -75dBm max.
Insertion Loss:
1.5dB max.
200Hz - 4000Hz
(600
ref., 600 load)
Frequency Response:
± 0.4dB max.
200Hz - 4000Hz
(600
ref., 600 load)
Return Loss:
>22dB (when using
300Hz - 4000Hz
recommended circuit).
Max. DC current
0mA
ENVIRONMENTAL & SAFETY SPECIFICATION
Voltage Breakdown:
Tested according to
EN60950 part 5.3.2.
(test voltage: 3000 Volts).
Storage temperature:
Tested to IEC 68-2-14:1984
test procedure Nb.
(temperature range -25°C to +85°C).
CIRCUIT SCHEMATIC
MECHANICAL SPECIFICATION
As this product is covered by a
BABT Certificate of Recognition
(CR0059) approvals time will be
reduced.
a