1.6- 5.6, III. Generation
Technology
183
Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de
9
Technology
Technical Data
Technische Daten
Applicable standards
Anwendbare Standards
Interface according to
CECC 22 240
Interface gem
Quality tested according to
IEC 60068
Qualittsprüfung gem
Electrical data
Elektrische Daten
Impedance
75
Wellenwiderstand
Frequency range (straight connectors)
0...12 GHz
Frequenzbereich (gerade Steckverbinder)
Return loss
≥ 33 dB @ DC to 1 GHz
≥ 27.5 dB @ 1 to 2 GHz
≥ 20.8 dB @ 2 to 4 GHz
Rückflussdmpfung
Insertion loss
≤ 0.1 x √ f (GHz) dB, DC to 4 GHz
Dmpfung
Insulation resistance
≥ 10 x 10 M
Isolationswiderstand
Center contact resistance
≤ 4.0 m
bergangswiderstand Innenleiter
Outer contact resistance
≤ 2.0 m
bergangswiderstand Auenleiter
Test voltage
1000 V rms
Prüfspannung
Working voltage
330 V rms
Betriebsspannung
RF- leakage
≥ 90 dB up to 1 GHz (slide- on version)
≥ 100 dB up to 1 GHz (screw- on version)
Schirmdmpfung
Mechanical data
Mechanische Daten
Mating cycles
≥ 500
Steckzyklen
Coupling torque
30 Ncm max.
Anzugsdrehmoment
Center contact captivation
axial:
≥ 30 N
Innenleiter Haltekraft
Engaging and disengaging force
2.2 N to 12 N (screw- on, slide- on)
18 N to 50 N (quick- lock)
Einsteck- und Ausziehkraft
Environmental data
Umweltdaten
Temperature range
- 40°C - +85°C
Temperaturbereich
Climatic class
IEC 60068- 2- 1 40/85/21
IEC 60068- 2- 2
IEC 60068- 2- 3
Klimaklasse
Vibration
IEC 60068- 2- 6
10 Hz to 2000 Hz, 100m/s
Vibration
Materials
Materialien
Outer contact
CuZn
Auenleiter
Spring loaded contact parts
CuBe
Federnde Kontaktteile
Dielectric
LCP or equivalent
Dielektrikum
Crimping ferrule
Soft copper
Crimphülse
Plating outer contact area
Au
Oberflche Kontaktzone Auenleiter
Plating center contact area
Au
Oberflche Kontaktzone Innenleiter
Plating other parts
Ni
Oberflche sonstige Teile
Rosenberger- connectors fulfill in principle the indicated data of the Tech-
nical Data. Individual values of connectors may deviate depending upon
application, design, type of cable, assembly method and execution. Specific
data sheets for particular products can be provided on request from your
Rosenberger sales partner.
Rosenberger- Steckverbinder erfüllen grundstzlich die in den Technischen
Daten angegebenen Daten. Je nach Anwendung, Bauart, Kabeltyp, Mon-
tageart und - ausführung knnen einzelne Werte von Steckverbindern
hiervon abweichen. Spezifische Datenbltter zu einzelnen Produkten
erhalten Sie auf Anfrage von Ihrem Rosenberger- Ansprechpartner.