SN54ALS574B, SN54AS574, SN54AS575
SN74ALS574B, SN74ALS575A, SN74AS574, SN74AS575
OCTAL D-TYPE EDGE-TRIGGERED FLIP-FLOPS WITH 3-STATE OUTPUTS
SDAS165B – JUNE 1982 – REVISED JULY 1995
5
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, V
CC
Input voltage, V
I
Voltage applied to a disabled 3-state output
Operating free-air temperature range, T
A
: SN54AS574, SN54AS575
7 V
7 V
5.5 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
–55
°
C to 125
°
C
0
°
C to 70
°
C
–65
°
C to 150
°
C
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
SN74AS574, SN74AS575
Storage temperature range
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
recommended operating conditions
SN54AS574
SN54AS575
SN74AS574
SN74AS575
UNIT
MIN
NOM
MAX
MIN
NOM
MAX
VCC
VIH
VIL
IOH
IOL
fclock*
Supply voltage
4.5
5
5.5
4.5
5
5.5
V
High-level input voltage
2
2
V
Low-level input voltage
0.8
0.8
V
High-level output current
–12
–15
mA
Low-level output current
32
48
mA
Clock frequency
0
100
0
90
MHz
t *
tw*
Pulse duration
CLK high
5
5.5
ns
CLK low
4
5.5
tsu*
Set p time before CLK
Setup time before CLK
↑
Data
′
AS575, CLR high or low
Data
′
AS575, CLR
3
5.5
ns
6.5
6.5
th*
Hold time after CLK
↑
3
3
ns
0
0
TA
* On products compliant to MIL-STD-883, Class B, this parameter is based on characterization data but is not production tested.
Operating free-air temperature
–55
125
0
70
°
C