IDT29FCT520AT/BT/CT/DT, 521AT/BT/CT/DT
MULTILEVEL PIPELINE REGISTERS
MILITARY AND COMMERCIAL TEMPERATURE RANGES
6.2
3
CAPACITANCE
(T
A
= +25
°
C, f = 1.0MHz)
Symbol
Parameter
(1)
C
IN
Input
Capacitance
C
OUT
Output
Capacitance
NOTE:
1. This parameter is measured at characterization but not tested.
ABSOLUTE MAXIMUM RATINGS
(1)
Symbol
Rating
V
TERM(2)
Terminal Voltage
with Respect to
GND
V
TERM(3)
Terminal Voltage
with Respect to
GND
T
A
Operating
Temperature
T
BIAS
Temperature
Under Bias
T
STG
Storage
Temperature
P
T
Power Dissipation
Commercial
–0.5 to +7.0
Military
–0.5 to +7.0
Unit
V
–0.5 to
V
CC
+0.5
–0.5 to
V
CC
+0.5
V
0 to +70
–55 to +125
°
C
–55 to +125
–65 to +135
°
C
–55 to +125
–65 to +150
°
C
0.5
0.5
W
I
OUT
DC Output
Current
–60 to +120 –60 to +120 mA
NOTES:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RAT-
INGS may cause permanent damage to the device. This is a stress rating
only and functional operation of the device at these or any other conditions
above those indicated in the operational sections of this specification is
not
implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability. No terminal voltage may exceed
V
CC
by +0.5V unless otherwise noted.
2. Input and V
CC
terminals only.
3. Outputs and I/O terminals only.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Commercial: T
A
= 0
°
C to +70
°
C, V
CC
= 5.0V
±
5%; Military: T
A
= –55
°
C to +125
°
C, V
CC
= 5.0V
±
10%
Symbol
Parameter
V
IH
Input HIGH Level
Guaranteed Logic HIGH Level
V
IL
Input LOW Level
Guaranteed Logic LOW Level
I
IH
Input HIGH Current
(4)
V
CC
= Max.
I
IL
Input LOW Current
(4)
V
CC
= Max.
I
OZH
High Impedance
(4)
V
CC
= Max.
I
OZL
Output Current
I
I
Input HIGH Current
(4)
V
CC
= Max., V
I
= V
CC
(Max.)
V
IK
Clamp Diode Voltage
V
CC
= Min., I
N
= –18mA
I
OS
Short Circuit Current
V
CC
= Max.
(3)
, V
O
= GND
V
OH
Output HIGH Voltage
V
CC
= Min.
V
IN
= V
IH
or V
IL
Test Conditions
(1)
Min.
2.0
—
—
—
—
—
—
—
–60
2.4
Typ.
(2)
—
—
—
—
—
—
—
–0.7
–120
3.3
Max.
—
0.8
±
1
±
1
±
1
±
1
±
1
–1.2
–225
—
Unit
V
V
μ
A
μ
A
μ
A
V
I
= 2.7V
V
I
= 0.5V
V
O
= 2.7V
V
O
= 0.5V
μ
A
V
mA
V
I
OH
= –6mA MIL.
I
OH
= –8mA COM’L.
I
OH
= –12mA MIL.
I
OH
= –15mA COM’L.
I
OL
= 32mA MIL.
I
OL
= 48mA COM’L.
2.0
3.0
—
V
OL
Output LOW Voltage
V
CC
= Min.
V
IN
= V
IH
or V
IL
—
0.3
0.5
V
V
H
I
CC
Input Hysteresis
Quiescent Power
Supply Current
—
—
—
200
0.01
—
1
mV
mA
V
CC
= Max.
V
IN
= GND or V
CC
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at V
CC
= 5.0V, +25
°
C ambient.
3. Not more than one output should be shorted at one time. Duration of the short circuit test should not exceed one second.
4. The test limit for this parameter is
±
5
μ
A at T
A
= -55
°
C.
2619 tbl 05
Conditions
V
IN
= 0V
Typ.
6
Max. Unit
10
pF
V
OUT
= 0V
8
12
pF
2619 lnk 04
2619 lnk 03