Document Number: 94242
For technical questions, contact: diodestech@vishay.com
www.vishay.com
Revision: 22-Jul-09
1
Schottky Rectifier,
2 x 30 A
62CTQ030PbF
Vishay High Power Products
FEATURES
150 °C TJ operation
Center tap TO-220 package
Low forward voltage drop
High frequency operation
High purity, high temperature epoxy encapsulation for
enhanced mechanical strength and moisture resistance
Guard ring for enhanced ruggedness and long term
reliability
Compliant to RoHS directive 2002/95/EC
Designed and qualified for industrial level
DESCRIPTION
This center tap Schottky rectifier has been optimized for low
reverse leakage at high temperature. The proprietary barrier
technology allows for reliable operation up to 150 °C junction
temperature. Typical applications are in switching power
supplies, converters, freewheeling diodes, and reverse
battery protection.
PRODUCT SUMMARY
IF(AV)
2 x 30 A
VR
30 V
TO-220AB
Anode
13
2
Base
common
cathode
2
Common
cathode
Anode
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL
CHARACTERISTICS
VALUES
UNITS
IF(AV)
Rectangular waveform (per device)
60
A
VRRM
30
V
IFRM
TC = 120 °C (per leg)
60
A
IFSM
tp = 5 s sine
1500
VF
30 Apk, TJ = 125 °C
0.44
V
TJ
Range
- 65 to 150
°C
VOLTAGE RATINGS
PARAMETER
SYMBOL
62CTQ030PbF
UNITS
Maximum DC reverse voltage
VR
30
V
Maximum working peak reverse voltage
VRWM
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
TEST CONDITIONS
VALUES
UNITS
Maximum average
forward current
per leg
IF(AV)
50 % duty cycle at TC = 120 °C, rectangular waveform
30
A
per device
60
Peak repetitive forward current per leg
IFRM
Rated VR, square wave, 20 kHz, TC = 127 °C
60
Maximum peak one cycle non-repetitive
surge current per leg
IFSM
5 s sine or 3 s rect. pulse
Following any rated load
condition and with rated
VRRM applied
1500
10 ms sine or 6 ms rect. pulse
300
Non-repetitive avalanche energy per leg
EAS
TJ = 25 °C, IAS = 3 A, L = 2.9 mH
13
mJ
Repetitive avalanche current per leg
IAR
Current decaying linearly to zero in 1 s
Frequency limited by TJ maximum VA = 1.5 x VR typical
3A
* Pb containing terminations are not RoHS compliant, exemptions may apply