![](http://datasheet.mmic.net.cn/110000/5962R9563002TXC_datasheet_3278141/5962R9563002TXC_1.png)
1
TM
HS-1840ARH-T
Radiation Hardened 16 Channel CMOS
Analog Multiplexer with High-Z Analog
Input Protection
Intersil’s Satellite Applications FlowTM (SAF) devices are fully
tested and guaranteed to 100kRAD Total Dose. These QML
Class T devices are processed to a standard flow intended
to meet the cost and shorter lead-time needs of large
volume satellite manufacturers, while maintaining a high
level of reliability.
The HS-1840ARH-T is a Radiation Hardened, monolithic 16
channel multiplexer constructed with the Intersil Rad-Hard
Silicon Gate, Dielectric Isolation process. It is designed to
provide a high input impedance to the analog source if
device power fails (open), or the analog signal voltage
inadvertently exceeds the supply by up to
±35V, regardless
of whether the device is powered on or off. Selection of one
of sixteen channels is controlled by a 4-bit binary address
plus an Enable-Inhibit input, which conveniently controls the
ON/OFF operation of several multiplexers in a system. All
inputs have electrostatic discharge protection.
Specifications
Specifications for Rad Hard QML devices are controlled by
the Defense Supply Center in Columbus (DSCC). The SMD
numbers listed below must be used when ordering.
Detailed Electrical Specifications for the HS-1840ARH-T
are contained in SMD 5962-95630. For more information,
visit us on our website at: www.intersil.com/
Intersil’s Quality Management Plan (QM Plan), listing all
Class T screening operations, is also available on our
website.
www.intersil.com/
Features
QML Class T, Per MIL-PRF-38535
Radiation Performance
- Gamma Dose (
γ) 1 x 105 RAD(Si)
- No Latch-Up, Dielectrically Isolated Device Islands
Improved rDS(ON) Linearity
Improved Access Time 1.5
s (Max) Over Temp and Rad
High Analog Input Impedance 500M
During Power Loss
(Open)
±35V Input Over Voltage Protection (Power On or Off)
Excellent in Hi-Rel Redundant Systems
Break-Before-Make Switching
Pinouts
HS1-1840ARH-T (SBDIP), CDIP2-T28
TOP VIEW
HS9-1840ARH-T (FLATPACK) CDFP3-F28
TOP VIEW
Ordering Information
ORDERING
NUMBER
PART
NUMBER
TEMP.
RANGE
(oC)
5962R9563002TXC
HS1-1840ARH-T
-55 to 125
HS1-1840ARH/Proto
-55 to 125
5962R9563002TYC
HS9-1840ARH-T
-55 to 125
HS9-1840ARH/Proto
-55 to 125
NOTE:
Minimum order quantity for -T is 150 units through
distribution, or 450 units direct.
+VS
NC
IN 16
IN 15
IN 14
IN 13
IN 12
IN 11
IN 10
IN 9
GND
(+5VS) VREF
ADDR A3
OUT
IN 8
IN 7
IN 6
IN 5
IN 3
IN 1
ENABLE
ADDR A0
ADDR A1
ADDR A2
-VS
IN 4
IN 2
28
27
26
25
24
23
22
21
20
19
18
17
16
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
28
27
26
25
24
23
22
21
20
19
18
17
16
15
+VS
NC
IN 16
IN 15
IN 14
IN 13
IN 12
IN 11
IN 10
IN 9
GND
(+5VS) VREF
ADDR A3
OUT
-VS
IN 8
IN 7
IN 6
IN 5
IN 4
IN 3
IN 2
IN 1
ENABLE
ADDR A0
ADDR A1
ADDR A2
Data Sheet
July 1999
FN4589.1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143
| Intersil (and design) is a trademark of Intersil Americas Inc.