Notes
1. Guaranteed by design, not tested.
2. MTR2805D is specified at 25°C only.
3. Up to 90% of the total output current/power is available from either output providing
the positive output is carrying at least 10% of the total output power.
4. Operation is limited below 16 V (see Figure 22).
5. Effect on negative Vout from 50%/50% loads to 80%/20% or 20%/80% loads.
6. Effect on negative Vout from 50%/50% loads to 90%/10% or 10%/90% loads. See
Figure 20.
7. Indefinite short circuit protection not guaranteed above 125°C case.
8. Recovery time is measured from application of the transient to point at which Vout
is within 1% of final value.
9. Tested on release from inhibit.
DUAL OUTPUT MODELS - STaNDaRD aND /ES
MTR2805D 2
MTR2812D
MTR2815D
units
parameter
ConDitions
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
output voltage
+ vout 4.850 5.00 5.150 11.88 12.00 12.12 14.85 15.00 15.15
vDC
- vout 4.825 5.00 5.172 11.58 12.00 12.42 14.47 15.00 15.53
output Current 3
eaCh output
0
2.5
4.5 1
0
1.25
2.25 1
0
—
1.80 1
a
vin = 16 to 40 vDC
total output
—
5
—
2.5
—
2.00
output poWer 3
eaCh output
0
—
22.5 1
0
—
27 1
0
—
27 1
W
vin = 16 to 40 vDC
total output
—
25
—
30
—
30
output ripple
tC = 25°C
—
20
80
—
30
80
—
25
80
mV p-p
10 khz - 2 mhz ± vout
tC = -55°C to +125°C
—
40
120
—
40
120
line regulation 4
+ vout
—
10
50
—
10
50
—
10
50
mV
vin = 16 to 40 vDC
- vout
—
50
100
—
50
150
—
50
180
loaD regulation
+ vout
—
5
50
—
15
50
—
15
50
mV
no loaD to Full
- vout
—
25
100
—
30
150
—
30
180
Cross regulation 1
see note 5
—
4
6
—
4
6
—
4
6
%
EFFECT ON -VOUT, 25°C
see note 6
—
7
12
—
4
8.3
—
3
8
input voltage
Continuous
16
28
40
16
28
40
16
28
40
vDC
no loaD to Full
TRANSIENT 50 msec.1
0
—
50
0
—
50
0
—
50
v
input Current
no loaD
—
35
50
–
50
75
—
50
75
mA
inhibiteD
—
3
8
—
3
8
—
3
8
input ripple Current
10 khz - 10 mhz
—
15
40
—
20
50
—
20
50
mA p-p
eFFiCienCy
tC = 25°C
76
78
—
78
81
—
80
83
—
%
balanCeD loaD
tC = -55°C to +125°C
—
76
—
77
—
loaD Fault 7
poWer Dissipation
short CirCuit
—
10
12
—
10
12
—
10
12
W
reCovery 1
—
1.4
5.0
—
1.4
5.0
—
1.4
5.0
ms
step loaD response
50% - 100% - 50%
transient
—
±200
±300
—
±150
±300
—
±200
±400
mV pk
± vout
reCovery 1, 8
—
100
200
—
100
200
—
100
200
s
step line
response 1
16 - 40 -16 vDC
transient
—
±200
±400
—
±200
±400
—
±400
±500
mV pk
± vout
reCovery 8
—
300
—
300
—
300
s
start-up 9
Delay
—
1.4
5
—
1.4
5
—
1.4
5
ms
overshoot
Full loaD 1
—
0
180
—
0
120
—
0
150
mV pk
no loaD 1
—
180
250
—
120
600
—
150
750
CapaCitive loaD 1
tC = 25°C
no eFFeCt on DC
perFormanCe
—
500
—
500
—
500
F
Electrical Characteristics: -55°C to +125°C TC, 28 VDC Vin, 100% load, free run, unless otherwise specified.
Crane Aerospace & Electronics Power Solutions
MTR Single, Dual and Triple DC/DC Converters
28 VOlT INPuT – 30 WaTT
www.craneae.com/interpoint
Page 9 of 22
MTR Rev H - 2011.03.17