Solid State Sensors
Hall Effect Vane Position Sensors
4AV Series
Honeywell
1
MICRO SWITCH Sensing and Control
1
1-800-537-6945 USA
1F
1-815-235-6847 International
1
1-800-737-3360 Canada
51
FEATURES
1
Operated by vane interrupter
1
–40 to
+
125
°
C temperature range
1
Current sinking output
1
Smaller size than 2AV
1
Four pin in-line printed circuit board
terminals or leadwires
1
Closely controlled differential to
predict pulse width
1
4.5 to 5.5 or 6 to 16 VDC power
supply
4AV ORDER GUIDE
Catalog Listings
Supply Voltage (VDC)
Supply Current (mA max.)
Output Type
Output Voltage (V)
Current per Output (mA)
Termination
4AV11C
4.5 to 5.5
7.0
Sink
0.4
4
PC Board
4AV12C
4.5 to 5.5
7.0
Sink
0.4
8
Leadwire
4AV11A
6 to 16
13.0
Sink
0.4
10
PC Board
4AV12A
6 to 16
13.0
Sink
0.4
20
Leadwire
AV MECHANICAL CHARACTERISTICS
Left
Operate
Series
a
4AV*
5,4/.213
* Operating characteristics of the 4AV are adjusted to produce a .100
±
.010 dimension between the operate
pointononesideoftheswitch,tothereleasepointontheotherside.Theactuatorcanbedesignedtoproducea
specific pulse width for timing or sequencing operations.
Mag.
Release
b
6,0/.237
Right
Operate
d
8,6/.337
Slope
Diff.
0,6/.024
Release
c
7,9/.313
L-R
Diff.
2,5/.100
Diff.
0,6/.024
VANE DIMENSIONS (mm/in.)
Thickness
1,0/.04
1,6/.06
Vane material:
Cold rolled steel, 1018 or low in carbon (annealed).
Min. Window
10,2/.40
10,2/.40
Min. Tooth
10,2/.40
6,3/.25
Min. Tooth
Depth
9,3/.37
MOUNTING DIMENSIONS
(For reference only)
BLOCK DIAGRAM
Leadwire
PC Board
GENERAL INFORMATION
AV vane operated integral magnet posi-
tion sensors are operated by passing a
ferrousvanethroughthegapbetweenthe
Hall sensor and the magnet, shunting the
magnetic flux away from the sensor. AVs
can be used as limit switches by oper-
ating with a single large vane; as tachom-
eter sensors by using toothed wheels; or
as synchronizing elements by using
cams or sectors. AV Series have many
features in common such as:
1
Operation by a low cost, easy to
fabricate ferrous vane
1
Magnet and sensor incorporated in
same rugged package
1
Sealed construction . . . unaffected by
dust or dirt
1
0 to 100 kHz operating speed . . . no
minimum speed of operation
1
On and Off times programmable by
vane dimensioning
1
Precision mechanical operating
characteristics
VANE OPERATION
1. With no vane in the gap the output is
conducting (Sinking is Low, Sourcing
is High).
2. Vane movement from left to right.
When leading edge reaches
‘‘
b’’, the
output stops conducting (Sinking
goes High, Sourcing goes Low).
3.
After leading edge reaches ‘‘b’’:
A. If the vane moves on through the
gap; when the trailing edge
reaches
‘‘
d’’, the output will be
conducting.
B. If direction of vane travel
reverses;
‘‘
a’’, output will be
conducting.
4. For vane movement from right to left,
output is non-conducting when the
leading edge reaches
‘‘
c’’, and is
conducting when the trailing edge
reaches
‘‘
a’’.
I