2001 Jun 22
9
BCcomponents
Product specification
Interference suppression film capacitors
MKP 338 6 Y2
CONSTRUCTION
Description
Low-inductive wound cell of metallized polypropylene
(PP) film, potted with epoxy resin in a flame-retardant
case
Radial leads, solder-coated
Small stand-off pips allow removal of solder flux etc.
during cleaning of the printed-circuit board.
Mounting
N
ORMAL
USE
The capacitors are designed for mounting on printed-circuit
boards. The capacitors packed in bandoliers are designed
for mounting on printed-circuit boards by means of
automatic insertion machines.
For detailed tape specifications refer to this handbook,
chapter
“
Packaging information
”
.
144x12(halfpage)
metal spray layer
MKP metallised polypropylene film
connecting wire
CBA313
3 SECTIONS
Fig.5 Construction for pitch
=
7.5 mm.
144x12(halfpage)
metal spray layer
MKP metallised polypropylene film
connecting wire
CBA312
2 SECTIONS
Fig.6 Construction for pitch
>
7.5 mm.
S
PECIFIC
METHOD
OF
MOUNTING
TO
WITHSTAND
VIBRATION
AND
SHOCK
In order to withstand vibration and shock tests, it must be
ensured that the stand-off pips are in good contact with the
printed-circuit board:
For pitches
≤
15 mm capacitors shall be mechanically
fixed by the leads.
For larger pitches the capacitors shall be mounted in the
same way and the body clamped.
S
PACE
REQUIREMENTS
ON
PRINTED
-
CIRCUIT
BOARD
The maximum length and width of film capacitors is shown
in Fig.7:
Eccentricity as in Fig.7. The maximum eccentricity is
smaller than or equal to the lead diameter of the product
concerned.
Product height with seating plane as given by
“
IEC 60717
”
as reference: h
max
≤
h
+
0.3 mm or
h
max
≤
h
’
+
0.3 mm.
Storage temperature
Storage temperature: T
stg
=
25 to
+
40
°
C with RH
maximum 80% without condensation.
RATINGS AND CHARACTERISTICS REFERENCE
CONDITIONS
Unless otherwise specified, all electrical values apply to an
ambient temperature of 23
±
1
°
C, an atmospheric pressure
of 86 to 106 kPa and a relative humidity of 50
±
2%.
For reference testing, a conditioning period shall be applied
over 96
±
4 hours by heating the products in a circulating air
oven at the rated temperature and a relative humidity not
exceeding 20%.
144x12(halfpage)
CBA116
eccentricity
lmax = l + 0.3 mm
bmax = b + 0.3 mm
Fig.7 Lay-out.