![](http://datasheet.mmic.net.cn/50000/4-1393682-2_datasheet_1783722/4-1393682-2_23.png)
Coaxial Cables
List of the coaxial cables that are listed in the various
connector series of this section.
Cable-Type Designation
Characteristic
Max. Cable
Dielectric Diameter (mm)/
VDE Designation2)
US Designation
IEC Designation
Impedance (
)
Outer Diameter (mm)
Material1)
Manufacturer des.
96-IEC
50
1.9
0.91max/PTFE
5YC5Ye 0.3/0.86
RG 178
50-1-1
50
2.1
0.87/PTFE
—
RG 196
50-1-2
50
2.25
1.71max/PTFE
5YK 0.51/1.68
RG 405
—
50
2.6
1.60max/PTFE
5YC5Ye 0.5/1.5
RG 316
50-2-1
50
2.8
1.60max/PE
2YCY 0.5/1.5
RG 174
—
50
3.0
1.52/PTFE
5YCC5Y 0.5/1.5
RD 316
—
50
3.6
3.01max/PTFE
5YK 0.9/3.0
RG 402
—
50
6.4
5.38max/PTFE
5YK 1.63/5.33
RG 401
—
75
2.67
1.68max/PTFE
5YC6Y 0.3/1.6
RG 179
75-2-1
75
3.0
1.60max/PTFE
—
RD 179
—
75
3.3
1.68max/Cell-FEP
06YCC(St)6Y 0.4/1.6
—
75
3.2
2.1max
—
ST 212
—
75
3.6
2.0max/Cell-PE
02Y(St)CY 0.45/2.0
—
75
4.0
2.0maxE/Cell-PE
02Y12YC(mS)C6Y 0.45/2.0
—
75
4.0
2.54max/PE
2YCY 0.4/2.5
—
75
4.8
2.54max/PE
2YCCY 0.4/2.5
—
75
5.0
2.54max/PE
2YC(mS)CY 0.4/2.5
—
75
6.1
4.25max/PE
2YCY 0.7/4.4
—
75
6.2
2.83max/PE
2YC(mS)CY 0.5/3.0
—
75
6.25
3.8max/PE
2YCY 0.58/3.7
RG 59
—
75
7.8
4.43max/PE
2YCCY 0.7/4.4
—
75
9.8
6.4/PE
2YCCY 1.0/6.5
—
75
9.8
6.4/PE
2YC(mS)CY 1.0/6.5
—
1)
Material label
PTFE
Polytetrafluorethylene
PE
Polyethylene
FEP
Perfluorethylene propylene
PFA
Perfluoralkoxy copolymer
2)
Mounting label of the VDE type numbers (from inside to outside)
Example:
6Y
C
(mS)
C
Y
0.7/4.0
-75
(r2/100)
vs gr
Dielectric
1st screen
Intermediate layer
2nd screen
Outer jacket
Diameter inner conductor/dielectric
Characteristic impedance
Max. reflection (r) in % / frequency in MHz
Specifications on inner conductor and/or jacket color
Explanation
Dielectric and Jacket
2Y = PE
5Y = PTFE
02Y = Cell PE
06Y = Cell FEP
6Y = FEP
Screen:
C = Cu braiding
K = Cu tape
Intermediate layer:
mS = magnetic screen
St = static screen
Specifications on inner
conductor:
vs = silver plated
staku = Bare copper-clad
steel wire
conductor
Jacket color:
gn = green
gr = grey
rt = red
ws = white
151
Catalog 1307191
Dimensions are in millimeters
Dimensions are shown for
USA: 1-800-522-6752
South America: 55-11-2103-6000
Revised 3-07
and inches unless otherwise
reference purposes only.
Canada: 1-905-470-4425
Hong Kong: 852-2735-1628
specified. Values in brackets
Specifications subject
Mexico: 01-800-733-8926
Japan: 81-44-844-8013
www.tycoelectronics.com
are standard equivalents.
to change.
C. America: 52-55-1106-0803
UK: 44-8706-080-208
RF Coax Connectors