M/A-COM, Inc.
North America:
Tel. (800) 366-2266
s
Asia/Pacific:
Tel. +85 2 2375 0618
s
Europe: Tel. +44 (1344) 869 595
Fax (800) 618-8883
Fax +85 2 2375 0350
Fax +44 (1344) 300 020
2
Specifications Subject to Change Without Notice.
Materials
OSMT Plug
Housing:
Polyphenylene Sulfide
Contacts:
Copper alloy
OSMT Cable Jack
Outer Contact:
Beryllium Copper
Inner Contact:
Beryllium Copper
Dielectric:
Polypropylene, GF
Finish
Plug and cable jack - Contacts: Gold plate over nickel plate
Frequency
dc - 6 GHz
Nominal Impedance
50 ohms
Voltage Rating
250 Volts (VRMS Maximum) @ Sea Level
VSWR (Mated Connectors Only)
1.20:1 Maximum @ 2 GHz
1.40:1 Maximum @ 6 GHz
Insulation Resistance
1000 Megohms Minimum
Dielectric Withstanding Voltage
500 Volts (VRMS Minimum) @ Sea Level
Contact Resistance (Connectors Only)
Center Contact
15 milliohms Maximum
Outer Contact
10 milliohms Maximum
Insertion Loss (Connectors Only)
.15dB Max. @ 6 GHz
Connector Durability
100 mating cycles
Tape/Reel Packaging (Plug)
12mm per EIA-481
Force to Engage
4.0 lbs. Max. (2.5 lbs. typ.)
Force to Disengage
4.5 lbs. Max. (3.0 lbs. typ.)
Temperature Rating (Mated Pair)
PVC Flexible Cable:
-40°C (-40°F) to +105°C (221°F)
FEP Flexible Cable:
-40°C (-40°F) to +125°C (257°F)
Resistance to Solder Heat
Infrared, convection and vapor phase solderable (plug only). Maximum reflow time/temperature not to exceed
260°C for 3 minutes.
Requirement
Detail
OSMT Specifications
General
Electrical
Mechanical
Environmental
Cable Specifications
1
Materials
PVC Flexible Cable (105°C)
FEP Flexible Cable (200°C)
Jacket:
Polyvinyl Chloride
Flourinated Ethylene Propylene
Shield:
Silver Plated Copper Wire,
38 AWG, 90% Min. Coverage
Dielectric:
PFA or FEP
Center Conductor:
Silver Plated Copper Clad Steel,
30 AWG
Minimum Bend Radius
9.5mm (.375 inch)
Insertion Loss (PVC and FEP Cable Only)
0.4 dB/ft., 1.3d B/m @ 500 MHz
1.3 dB/ft., 4.3 dB/m @ 4 GHz
0.6 dB/ft., 2.0 dB/m @ 1 GHz
1.7 dB/ft., 5.6 dB/m @ 6 GHz
0.9 dB/ft., 3.0 dB/m @ 2 GHz
Center Conductor Resistance
.26 Ohms per foot average.
(PVC and FEP Cable Only)
1. M/A-COM has design control and all data contained herein is subject to change without notice.
OUTER
JACKET
CENTER
CONDUCTOR
DIELECTRIC
1.9 mm
(.075) DIA.
.73 mm
(.028) DIA.
SHIELD
(BRAID)
.254 mm (.010)
DIA. REF
Decimal inch equivalents are shown in parentheses for general information only.