uA9637AC
DUAL DIFFERENTIAL LINE RECEIVER
SLLS111B – SEPTEMBER 1980 – REVISED MAY 1995
2–2
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1)
Input voltage, V
I
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
(see Note 2)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
(see Note 1)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low-level output current, I
OL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total dissipation
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds
–0.5 V to 7 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±
15 V
±
15 V
–0.5 V to 5.5 V
50 mA
See Dissipation Rating Table
0
°
C to 70
°
C
–65
°
C to 150
°
C
260
°
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES:
1. All voltage values, except differential input voltage, are with respect to the network ground terminal.
2. Differential input voltage is measured at the noninverting input with respect to the corresponding inverting input.
DISSIPATION RATING TABLE
PACKAGE
TA
≤
25
°
C
POWER RATING
OPERATING FACTOR
ABOVE TA = 25
°
C
5.8 mW/
°
C
8.0 mW/
°
C
TA = 70
°
C
POWER RATING
TA = 125
°
C
POWER RATING
D
725 mW
464 mW
—
P
1000 mW
640 mW
—
recommended operating conditions
MIN
4.75
NOM
MAX
5.25
±
7
70
UNIT
V
V
°
C
Supply voltage, VCC
Common-mode input voltage, VIC
Operating free-air temperature, TA
electrical characteristics over recommended ranges of supply voltage, common-mode input
voltage, and operating free-air temperature (unless otherwise noted)
5
0
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
0.2
UNIT
VIT+
Positive-going input threshold voltage
See Note 3
V
0.4
VIT–
Negative going input threshold voltage
Negative-going input threshold voltage
See Note 3
–0.2
–0.4§
V
Vhys
VOH
VOL
Hysteresis voltage (VIT+–VIT–)
High-level output voltage
70
mV
VID = 0.2 V,
VID = –0.2 V,
VCC = 0 to 5.5 V,
See Note 4
IO = –1 mA
IO = 20 mA
VI = 10 V
VI = –10 V
VID = 0.2 V
No load
2.5
3.5
V
Low-level output voltage
0.35
0.5
V
II
Input current
1.1
3.25
mA
–1.6
–3.25
IOS
ICC
All typical values are at VCC = 5 V, TA = 25
°
C.
§The algebraic convention, in which the less positive (more negative) limit is designated as minimum, is used in this data sheet for threshold levels
only.
Only one output should be shorted at a time, and duration of the short circuit should not exceed one second.
NOTES:
3. The expanded threshold parameter is tested with a 500-
resistor in series with each input.
4. The input not under test is grounded.
Short-circuit output current
VO = 0,
VID = –0.5 V,
–40
–75
–100
mA
Supply current
35
50
mA