STO150
TCXO
Corning Frequency Control Worldwide Data Book 2001
v1.1.2002-01-03
Corning Frequency Control Inc. 100 Watts Street Mt. Holly Springs, PA 17065 Tel 1-717-486-3411 Fax 1-717-486-5920 www.corningfrequency.com
Corning Frequency Control GmbH & Co. KG Landstrasse D-74924 Neckarbischofsheim, Germany Tel +49-7268-801-0 Fax +49-07268-801-281 www.corningfrequency.de
1 / 4
Typical Applications
Features
PCS Base Stations
Mechanical Control
Land Mobile Radio
EFC Optional
Cellular Telephony
Standard Surface Mount Package
Radio in the Local Loop
Wide Temperature Range
Digital Switching
Wide Frequency Range
Frequency Range
10 MHz – 80 MHz
Standard Frequencies
10; 13; 16.384; 19.44; 20; 25.92; 38.88MHz
Frequency stabilities
Parameter
Code I
Frequency stability
Operating temp range
07
± 2.0 ppm
08
± 1.0 ppm
-40 ... +85°
03
± 2.0 ppm
04
± 1.0 ppm
-20 ... +70°C
05
± 1.0 ppm
vs. Operating temperature range
06
± 0.5 ppm
0 ... 50°C
Parameter
Value
Condition
Vs. Supply voltage change
vs. Load change
vs. Aging / year
< ± 0.2 ppm
< ± 1.0 ppm
Vs ± 5%
Load ± 10%
Parameter
Option I
Value
Condition
Overall tolerance 15 years
S3
<
± 4.6 ppm
See Datasheet
STO150S3
Frequency tuning
Parameter
Option II
Value
Condition
Mechanical (No EFC)
Blank
>
± 3.0 ppm
(internal trimmer)
Electrical freq. control (EFC)
> ± 5.0 ppm
Note 1
Voltage range (Vc)
U
0.5 to 4.5 V
@ VS=5.0 V
0.3 to 3.0 V
@ VS= 3.3 V
Pulling slope
positive
Freq. control input impedance
>10 k
4
RF Output
Parameter
Code III
Value
Condition
Signal
HCMOS
Load
25pF ± 10%
@ < 20MHz
15pF ± 10%
@
≥ 20MHz
Duty cycle
06
40/60%
@ VS/2
Subharmonics
< -45dBc
@ > 33MHz
Supply Voltage
Parameter
Code II
Value
Condition
Supply voltage (VS)
05
5.0 V ± 5%
Current consumption
< 3 mA
Clipped Sinewave
5mA to 50mA
HCMOS
Supply voltage (VS)
33
3.3 V ± 5%
Current consumption
< 3 mA
Clipped Sinewave
5mA to 50mA
HCMOS