DC and AC Characteristics
September 5, 2002
Document #: 38-12010 CY Rev. ** CMS Rev. 3.20
135
13.2.8
DC Programming Specifications
Table 114:
DC Programming Specifications
Symbol
DC Programming Specifications
Minimum
Typical
Maximum
Unit
I
ccp
Supply Current During Programming or Verify
-
5
20
mA
V
ilp
Input Low Voltage During Programming or Verify
-
-
0.8
V
V
ihp
Input High Voltage During Programming or Verify
2.2
-
-
V
I
ilp
Input Current when Applying Vilp to P1[0] or P1[1]
During Programming or Verify
-
-
0.2
mA
I
ihp
Input Current when Applying Vihp to P1[0] or
P1[1] During Programming or Verify
-
-
1.5
1
1.
2.
Driving internal pull-down resistor.
A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1
blocks of 50,000 maximum cycles each, 36x2 blocks of 25,000 maximum cycles each, or 36x4 blocks of 12,500
maximum cycles each (and so forth to limit the total number of cycles to 36x50,000 and that no single block ever
sees more than 50,000 cycles).
mA
V
olv
Output Low Voltage During Programming or Verify -
-
V
ss
+ 0.75
V
V
ohv
Output High Voltage During Programming or
Verify
V
cc
- 1.0
-
V
cc
V
Flash
enpb
Flash Endurance (Per Block)
50,000
-
-
E/W Cycles
per Block
Flash
ent
Flash Endurance (Total)
2
The CY8C25xxx/26xxx family of PSoC devices uses an adaptive algorithm to enhance endurance over the indus-
trial temperature range (-40°C to +85°C ambient). Any temperature range within a 50°C span between 0°C and
85°C is considered constant with respect to endurance enhancements. For instance, if room temperature (25°C)
is the nominal operating temperature, then the range from 0°C to 50°C can be approximated by the constant value
25 and a temperature sensor is not needed.
For the full industrial range, the user must employ a temperature sensor User Module (FlashTemp) and feed the
result to the temperature argument before writing. Refer to the Flash APIs Application Note AN2015 at http://
www.cypressmicro.com under Support or Active Design Support for more information.
1,800,000
E/W Cycles
Flash
dr
Flash Data Retention (After Cycling)
10
-
-
Years