6
MX27L1000
P/N: PM0238
REV. 3.6 , AUG. 20, 2001
DC CHARACTERISTICS
SYMBOL
PARAMETER
MIN.
MAX.
UNIT
CONDITIONS
VOH
Output High Voltage
VCC - 0.3
V
IOH = -100uA VCC=3.0V
VOL
Output Low Voltage
0.3
V
IOL = 2.1mA, VCC = 3.0V
VIH
Input High Voltage
2.0
Vcc + 0.5
V
VIL
Input Low Voltage
-0.3
0.6
V
2.7V < VCC < 3.6V
ILI
Input Leakage Current
-10
10
uA
VIN = 0 to 3.6V
ILO
Output Leakage Current
-10
10
uA
VOUT = 0 to 3.6V
ICC3
VCC Power-Down Current
10
uA
CE = VCC
±
0.3V
ICC2
VCC Standby Current
0.25
mA
CE = VIH
ICC1
VCC Active Current
20
mA
CE = VIH, f=5MHz, lout = OmA,
Vcc=3.6V
IPP
Supply Current Read
10
uA
CE = OE = VIL, VPP = VCC
NOTICE:
Stresses greater than those listed under ABSOLUTE
MAXIMUM RATINGS may cause permanent damage to the
device. This is a stress rating only and functional operation
of the device at these or any other conditions above those
indicated in the operational sections of this specification is
not implied. Exposure to absolute maximum rating
conditions for extended period may affect reliability.
NOTICE:
Specifications contained within the following tables are
subject to change.
DC/AC Operating Conditions for Read Operation
ABSOLUTE MAXIMUM RATINGS
RATING
Ambient Operating Temperature -40
o
C to 85
o
C
Storage Temperature
Applied Input Voltage
Applied Output Voltage
VCC to Ground Potential
V9 & VPP
VALUE
-65
o
C to 125
o
C
-0.5V to 7.0V
-0.5V to VCC+0.5V
-0.5V to 7.0V
-0.5V to 13.5V
MX27L1000
-90
-12
-15
-20
-25
Operating Temperature
Commercial
0
°
C to 70
°
C
0
°
C to 70
°
C
0
°
C to 70
°
C
0
°
C to 70
°
C
0
°
C to 70
°
C
Industrial
-40
°
C to 85
°
C
-40
°
C to 85
°
C -40
°
C to 85
°
C
-40
°
C to 85
°
C -40
°
C to 85
°
C
Vcc Power Supply
2.7V to 3.6V
2.7V to 3.6V
2.7V to 3.6V
2.7V to 3.6V
2.7V to 3.6V
CAPACITANCE
TA = 25
o
C, f = 1.0 MHz (Sampled only)
SYMBOL
PARAMETER
CIN
Input Capacitance
COUT
Output Capacitance
CVPP
VPP Capacitance
TYP.
8
8
18
MAX.
12
12
25
UNIT
pF
pF
pF
CONDITIONS
VIN = 0V
VOUT = 0V
VPP = 0V