TYPICAL CHARACTERISTICS
Output Voltage Temperature Coefficient
100 ppm/°C typical
Input to Output Capacitance
100 to 170 pF typical
Undervoltage Lockout
8 V input typical
Current Limit
125% of full load typical
Isolation
100 megohm minimum at 500 V
Conversion Frequency (kHz)
25°C
300 min, 370 typ, 450 max
–55°C to +125°C
270 min, 370 typ, 470 max
Inhibit Pin Voltage (unit enabled)
7 to 12 V
RECOMMENDED OPERATING CONDITIONS
Input Voltage Range
12 to 50 VDC continuous
80 V for 120 msec transient
(70 V for 15 V single and dual models)
Case Operating Temperature (Tc)
–55°C to +125°C full power
–55°C to +135°C absolute
Derating Output Power/Current
Linearly from 100% at 125C° to 0% at 135 C
ABSOLUTE MAXIMUM RATINGS
Input Voltage
12 to 50 V
Output Power
1.5 watts
Capacitive Load
200 μF single output models
100 μF each output, dual output models
Lead Soldering Temperature
Reflow 220°C 30 sec. max
SN60, 62 or 63 recommended solder
Hand solder 300°C 10 sec. max per lead
Storage Temperature Range (Case)
–65°C to +150°C
INHIBIT
B2-94
MGH SERIES
1.5 WATT
DC/DC C
ONVERTERS
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Inhibit:TTL Open Collector
Logic low (output disabled)
Logic low voltage
≤
0.8 V
Inhibit pin current 1 mA max
Referenced to input common
Logic high (output enabled) open collector
SINGLE OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
1
MGH2805S
TYP
5
5
—
—
MGH2812S
TYP
12
12
—
—
MGH2815S
TYP
15
15
—
—
CONDITIONS
Tc = 25°C
Tc = –55°C TO +125°C
V
IN
= 12 to 50 VDC
V
IN
= 12 to 50 VDC
10 kHz - 2 MHz
Tc = –55°C TO +125°C
VIN = 12 to 50 VDC
Tc = –55°C TO +125°C
10% TO FULL LOAD
Tc = –55°C TO +125°C
50% TO FULL LOAD
Tc = –55°C TO +125°C
CONTINUOUS
TRANSIENT 120 ms
NO LOAD
Tc = –55°C TO +125°C
FULL LOAD
Tc = –55°C TO +125°C
INHIBITED
Tc = –55°C TO +125°C
10k Hz - 10 MHz
Tc = –55°C TO +125°C
Tc = 25°C
Tc = –55°C TO +125°C
POWER DISSIPATION
Tc = –55°C TO +125°C
RECOVERY
Tc = -–55°C TO +125°C
TRANSIENT
Tc = –55°C TO +125°C
RECOVERY
Tc = –55°C TO +125°C
TRANSIENT
Tc = –55°C TO +125°C
RECOVERY
Tc = –55°C TO +125°C
DELAY
Tc = –55°C TO +125°C
OVERSHOOT
Tc = –55°C TO +1 25°C
MIN
4.95
4.80
0
0
MAX
5.05
5.20
300
1.5
MIN
11.88
11.52
0
0
MAX
12.12
12.48
125
1.5
MIN
14.85
14.40
0
0
MAX
15.15
15.60
100
1.5
UNITS
VDC
OUTPUT CURRENT
OUTPUT POWER
mA
W
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
72
69
—
—
—
—
–400
–500
—
—
–400
–500
—
—
—
—
—
—
45
65
35
40
350
380
100
115
28
—
5.5
6.0
70
73
2.3
2.4
100
130
77
75
1.3
1.4
3.0
3.5
185
185
125
125
170
180
0.75
0.75
7
10
0
0
150
300
100
120
700
800
200
300
50
80
10
11
74
78
3.2
3.5
200
250
—
—
2.0
2.3
12
15
400
500
500
600
400
500
3.0
4.0
20
40
100
150
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
74
72
—
—
—
—
–700
–800
—
—
–900
–1000
—
—
—
—
—
—
50
70
60
70
600
640
145
160
28
—
6.0
6.5
68
70
2.3
2.4
100
150
79
77
2.0
2.2
3.5
3.5
350
380
130
130
400
400
0.6
0.6
7
10
0
0
200
300
200
250
1300
1400
300
400
50
80
10
12
72
74
3.2
3.5
200
250
—
—
3.2
3.5
15
20
700
800
500
600
900
1000
2.5
3.0
20
40
250
350
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
—
—
74
72
—
—
—
—
–700
–800
—
—
–750
–850
—
—
—
—
—
—
35
50
70
80
700
760
165
185
28
—
6.0
6.5
68
70
2.3
2.4
100
150
79
77
2.3
2.5
4.0
4.0
350
380
140
180
400
450
0.47
0.5
7
10
0
0
150
250
300
350
1500
1600
350
450
50
70
11
12
72
74
3.2
3.5
200
250
—
—
3.7
4.0
18
20
700
800
600
750
750
850
2.0
2.5
20
40
300
450
mV p-p
mV
LOAD REGULATION
mV
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
VDC
V
mA
INPUT RIPPLE
CURRENT
EFFICIENCY
mA p-p
%
LOAD FAULT
3, 4
W
ms
STEP LOAD
RESPONSE
5
50 %–100%– 50%
mV pk
μs
STEP LINE
RESPONSE
5
12 TO 50 TO 12 V
IN
mV pk
ms
START-UP
0 TO 28 VDC
ms
mV pk
Notes
1. Specified at 50% of full load.
2. Lin = 2 μH
3. Max. duration of short circuit: 25°C– 90 seconds; 125°C – 30 seconds.
4. Load fault is a short circuit (<50 mohms). Recovery into resistive full load.
5. Input step transition
≥
10 μs.Recovery is time to settle to within 1% of Vout
final value.