4
TABLE 2. LIGHTNING SURGE TESTS
V
OPEN
(RMS)
I
SHORT
(AMP)
R
S
(
)
WAVEFORM
(
μ
s)
TEST
CONDITIONS
NO.
OF TESTS
EXPECTED
CURRENT
±
1kV
100
10
10/1000
Tip to Source, Ring to Gnd
25 times
40A
±
1kV
100
10
10/1000
Ring to Source, Tip to Gnd
25 times
40A
±
1kV
100
10
10/1000
Tip and Ring to Source
25 times
40A
±
2.5kV
500
5
2/10
Tip to Source, Ring to Gnd
10 times
125A
±
2.5kV
500
5
2/10
Ring to Source, Tip to Gnd
10 times
125A
±
2.5kV
500
5
2/10
Tip and Ring to Source
10 times
125A
TEST PROCEDURE FOR TEST NO. 1 TO 12
1. With PTC in circuit.
2. Collect pre-test data on open tip and ring voltage and loop current readings with 600
load for V
BH
and V
BL
mode and record the data.
3. Set the scope settings.
4. Store the V
P
waveforms on scope screen when first applying the test signal and record the data.
5. Continue the surge test until it is complete.
6. Collect post-test data on open tip and ring voltage and loop current readings with 600
load for V
BH
and V
BL
mode and record the data.
7. The DUT passes the test, if the difference between the pre and post-test data is less than 5%. Otherwise, the DUT fails the test.
TABLE 3. AC POWER CROSS TESTS
V
OPEN
(RMS)
I
SHORT
(AMP)
R
S
(
)
TEST
CONDITIONS
TEST
DURATION
EXPECTED
CURRENT
50
0.330
150
Tip to Source, Ring to Gnd
15 minutes
300mA
50
0.330
150
Ring to Source, Tip to Gnd
15 minutes
300mA
50
0.330
150
Tip and Ring to Source
15 minutes
300mA
100
0.170
600
Tip to Source, Ring to Gnd
15 minutes
160mA
100
0.170
600
Ring to Source, Tip to Gnd
15 minutes
160mA
100
0.170
600
Tip and Ring to Source
15 minutes
160mA
200
0.330
600
Tip to Source, Ring to Gnd
1 sec, 60 times
320mA
200
0.330
600
Ring to Source, Tip to Gnd
1 sec, 60 times
320mA
200
0.330
600
Tip and Ring to Source
1 sec, 60 times
320mA
400
0.670
600
Tip to Source, Ring to Gnd
1 sec, 60 times
630mA
400
0.670
600
Ring to Source, Tip to Gnd
1 sec, 60 times
630mA
400
0.670
600
Tip and Ring to Source
1 sec, 60 times
630mA
600
1
600
Tip to Source, Ring to Gnd
1 sec, 60 times
950mA
600
1
600
Ring to Source, Tip to Gnd
1 sec, 60 times
950mA
600
1
600
Tip and Ring to Source
1 sec, 60 times
950mA
Application Note 9842