PCB Relay
G5SB
Specifications
■
Coil Ratings
■
Contact Ratings
Note:
P level:
λ
60=0.1 x 10
–6
operation (with an operating frequency of 120 operations/min.)
■
Characteristics
Note: 1.
The data shown above are initial values.
2.
The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3.
The operating time is possible with the operating voltage imposed with no contact bounce at an ambient temperature of 23
°
C.
4.
The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5.
The electrical life data items shown are possible at 23
°
C.
Rated voltage
Rated current
Coil resistance
Must operate voltage
Must release voltage
Maximum voltage
Power consumption
5 VDC
80 mA
63
75% max. of rated voltage
5% min. of rated voltage
110% of rated voltage
Approx. 400 mW
9 VDC
44.4 mA
202
12 VDC
33.3 mA
360
24 VDC
16.7 mA
1,440
Load
Rated load
Resistive load
3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Ag alloy
5 A (NO)/3 A (NC)
250 VAC, 30 VDC
5 A (NO)/3 A (NC)
1,250 VA, 150 W (NO)
750 VA, 30 W (NC)
10 mA at 5 VDC
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Insulation resistance (See note 4.)
Dielectric strength
100 m
max. initial
10 ms max.
5 ms max.
1,000 M
min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 x 50
μ
s)
Destruction: 10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:
1,000 m/s
2
(approx. 100G)
Malfunction:
Energized: 100 m/s
2
(approximately 10G)
Non-energized: 100 m/s
2
(approximately 10G)
Mechanical: 5,000,000 operations (18,000 operations per hour)
Electrical:
200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations:
5 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations:
5 A (NO) at 250 VAC resistive load
10,000 operations:
3 A (NC) at 250 VAC resistive load
10,000 operations:
5 A (NO)/3 A (NC) at 30 VDC resistive load
Switching frequency: 1,800 operations per hour
Operating:
–40
°
C to 70
°
C with no icing or condensation
Operating:
5% to 95%
Approx. 6.5 g
Impulse withstand voltage
Vibration resistance
Shock resistance
Life expectancy (See note 5.)
Ambient temperature
Ambient humidity
Weight