AMD
MACH230-10 (Com’l)
8
ABSOLUTE MAXIMUM RATINGS
Storage Temperature
Ambient Temperature
With Power Applied
. . . . . . . . . . . . .
Supply Voltage with
Respect to Ground
. . . . . . . . . . . . .
DC Input Voltage
. . . . . . . . . . . .
DC Output or I/O
Pin Voltage
. . . . . . . . . . . . . . . .
Static Discharge Voltage
Latchup Current
(T
A
= 0
°
C to 70
°
C)
. . . . . . . . . . . . . . . . . . . . .
–65
°
C to +150
°
C
. . . . . . . . . . .
–55
°
C to +125
°
C
–0.5 V to +7.0 V
–0.5 V to V
CC
+ 0.5 V
–0.5 V to V
CC
+ 0.5 V
. . . . . . . . . . . . . . . .
2001 V
200 mA
Stresses above those isted under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability. Pro-
gramming conditions may differ.
OPERATING RANGES
Commercial (C) Devices
Ambient Temperature (T
A
)
Operating in Free Air
Supply Voltage (V
CC
)
with Respect to Ground
0
°
C to +70
°
C
. . . . . . . . . . . . . .
+4.75 V to +5.25 V
. . . . . . . .
Operating ranges define those limits between which the func-
tionality of the device is guaranteed.
DC CHARACTERISTICS over COMMERCIAL operating ranges unless otherwise specified
Parameter
Symbol
Parameter Description
Test Conditions
I
OH
= –3.2 mA, V
CC
= Min
V
IN
= V
IH
or V
IL
V
OL
Output LOW Voltage
I
OL
= 16 mA, V
CC
= Min
V
IN
= V
IH
or V
IL
V
IH
Input HIGH Voltage
Guaranteed Input Logical HIGH
Voltage for all Inputs (Note 1)
V
IL
Input LOW Voltage
Guaranteed Input Logical LOW
Voltage for all Inputs (Note 1)
I
IH
Input HIGH Current
V
IN
= 5.25 V, V
CC
= Max (Note 2)
I
IL
Input LOW Current
V
IN
= 0 V, V
CC
= Max (Note 2)
I
OZH
Off-State Output Leakage
V
OUT
= 5.25 V, V
CC
= Max
Current HIGH
V
IN
= V
IH
or V
IL
(Note 2)
I
OZL
Off-State Output Leakage
V
OUT
= 0 V, V
CC
= Max
Current LOW
V
IN
= V
IH
or V
IL
(Note 2)
I
SC
Output Short-Circuit Current
V
OUT
= 0.5 V, V
CC
= Max (Note 3)
I
CC
Supply Current
V
IN
= 0 V, Outputs Open (I
OUT
= 0 mA)
V
CC
= 5.0 V, f = 25 MHz, T
A
= 25
°
C
(Note 4)
Min
Typ
Max
Unit
V
OH
Output HIGH Voltage
2.4
V
0.5
V
2.0
V
0.8
V
10
–10
10
μ
A
μ
A
μ
A
–10
μ
A
–30
–130
mA
mA
235
Notes:
1. These are absolute values with respect to device ground and all overshoots due to system and/or tester noise are included.
2. I/O pin leakage is the worst case of I
IL
and I
OZL
(or I
IH
and I
OZH
).
3. Not more than one output should be shorted at a time. Duration of the short-circuit should not exceed one second.
V
OUT
= 0.5 V has been chosen to avoid test problems caused by tester ground degradation.
4. This parameter is measured with a 16-bit up/down counter pattern. This pattern is programmed in each PAL block and